3 assays found tagged with eBioscience

Mouse IL-1ß Platinum ELISA

Quantitative analysis of samples using a Five Parameter Logistic (5PL) curve fit in accordance with eBioscience Mouse IL 1ß Platinum ELISA kit. This analysis optionally includes a background correction step. If a blank group is included on your layout, the mean of the blank replicates is first subtracted from the raw data measurements (the corrected values are then used in the fit). The standard data points (concentration vs. measurement) are plotted on semi-log axes and a 5PL is fit through the points. The concentrations of the samples are determined from the fit with any specified dilution factors applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Human IL-6 ELISA

Quantitative analysis of samples using a Five Parameter Logistic (5PL) curve fit in accordance with eBioscience Human Interleukin-6 (IL 6) ELISA kit. This analysis optionally includes a background correction step. If a blank group is included on your layout, the mean of the blank replicates is first subtracted from the raw data measurements (the corrected values are then used in the fit). The standard data points (concentration vs. measurement) are plotted on semi-log axes and a 5PL is fit through the points. The concentrations of the samples are determined from the fit with any specified dilution factors applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Human TNF-a High Sensitivity ELISA

Quantitative analysis of samples using a Five Parameter Logistic (5PL) curve fit in accordance with eBioscience TNF-a High Sensitivity ELISA kit. This analysis optionally includes a background correction step. If a blank group is included on your layout, the mean of the blank replicates is first subtracted from the raw data measurements (the corrected values are then used in the fit). The standard data points (concentration vs. measurement) are plotted on semi-log axes and a 5PL is fit through the points. The concentrations of the samples are determined from the fit with any specified dilution factors applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.