4 assays found tagged with Monobind

Monobind Thyrotroptin

Quantitative determination of thyrotropic concentration in human serum. Data analysis is performed in accordance with Monobind's TSH kit as follows: The absorbance values of the replicate serum references are plotted. A four parameter logistic curve is fitted to these replicated measurements. The average of each unknown group is calculated and the concentration is determined from the curve with any specified dilution factors applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Monobind Progesterone

Quantitative determination of progesterone concentration in serum or plasma. Data analysis is performed in accordance with Monobind's Progesterone Test Sytem as follows: The absorbance values of the replicate serum references are plotted. A four parameter logistic curve is fitted to these replicated measurements. The average of each unknown group is calculated and the concentration is determined from the curve with any specified dilution factors applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Monobind Estradiol CLIA

Quantitative determination of estradiol concentration in human serum or plasma by chemiluminescence immunoassay. Data analysis is performed in accordance with Monobind's estradiol kit as follows: The measurements of the replicated serum references are plotted. A five parameter logistic (5PL) curve is fitted to these replicated measurements. The average of each unknown group is calculated and the concentration is determined from the curve with any specified dilution factors applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

Monobind Testosterone

Quantitative determination of progesterone concentration in serum or plasma. Data analysis is performed in accordance with Monobind's Testosterone Test Sytem as follows: The absorbance values of the replicate serum references are plotted. A four parameter logistic curve is fitted to these replicated measurements. The average of each unknown group is calculated and the concentration is determined from the curve with any specified dilution factors applied. The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.