Most popular assay tools:

Four Parameter Logistic Curve

Quantitative analysis of samples using a Four Parameter Logistic (4PL) curve fit suitable for calculating concentrations from symmetrical sigmoidal calibrators. This method is widely used and cited in data analysis for typical ELISAs. This analysis optionally includes a background correction step. If a blank group is included on your layout, the mean of the blank replicates is first subtracted from the raw data measurements (the corrected values are then used in the fit). The standard data points (concentration vs. measurement) are plotted on semi-log axes and a 4PL is made through the points. The concentrations of the samples are determined from the fit with any specified dilution factors applied. Note, the concentration units are unspecified; use whichever units are applicable for your standards (the calculated concentrations will use these same unspecified units). The %CV, Standard Deviation and Standard Error are calculated for each replicated sample. Samples outside the range of the standards or the fit (greater than the upper asymptote or below the lower asymptote) are highlighted in yellow.

26 assays found matching "salimetrics":

Salivary Cortisol (µg/dL)

Competitive enzyme immunoassay (EIA) for the quantitative measurement of salivary cortisol (µg/dL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.

Salimetrics 17a-Hydroxyprogesterone

Competitive immunoassay for the quantitative measurement of Salimetrics 17a-Hydroxyprogesterone (pg/mL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.

Salimetrics Androstenedione

Competitive immunoassay for the quantitative measurement of androstenedione (pg/mL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.

Salimetrics Cortisol

Competitive immunoassay for the quantitative measurement of cortisol (µg/dL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.

Salimetrics Cotinine

Competitive immunoassay for the quantitative measurement of cotinine (ng/mL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.

Salimetrics DHEA

Competitive immunoassay for the quantitative measurement of DHEA (pg/mL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.

Salimetrics DHEA-S

Competitive immunoassay for the quantitative measurement of DHEA-S (pg/mL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.

Salimetrics High Sensitivity Estradiol

Competitive immunoassay for the quantitative measurement of estradiol (pg/mL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.

Salimetrics Estriol

Competitive immunoassay for the quantitative measurement of estriol (pg/mL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.

Salimetrics Estrone

Competitive immunoassay for the quantitative measurement of estrone (pg/mL). Calculations are made by subtracting the mean of the NSB measurements from the provided optical densities. The B/B0 is calculated from the corrected values using the mean of the B0 group. Concentrations are calculated using a Four Parameter Logistic Fit (4PL) and dilution factors are applied.
<< First< Previous
Page 1 of 3 (26 assays)
Next >Last >>